WEGO - Wide Band Air Fuel Ratio Meters with Display and Data Logging - Daytona-Sensors - DS112002 - WEGO III Wide-band Exhaust Gas Oxygen Sensor System - Automotive -
  Home » Daytona Sensors » WEGO - Wide Band Air Fuel Ratio Meters with Display and Data Logging » DS112002 My Cart  |  Checkout   
      Our Products      
Products By Vehicle->
Second Hand Pros Pro Parts->
Slip Yokes
Gift Ideas->
AN Fittings & Hose->
Brakes & Line Kits->
Chassis, Suspension & Rodends->
Daytona Sensors->
  Capacitive Discharge Ignition Systems
  Nitrous Controllers
  SmartSpark LS Ignition Module
  TC-1 Turbo Controller and Vehicle Data Logger
  WEGO - Wide Band Air Fuel Ratio Meters with Display and Data
Detailing Products->
Engine Components & Accessories->
Fasteners->
Fuel System & Components->
Heat Barriers & Wraps
James's Collectible Corner->
Methanol/Water Injection->
Performance Electric->
Performance Exhaust
Performance Ignition->
Performance Cooling->
Undercover Innovations Panels->
JLT Performance Cold Air Kits
Oils, ATF & Other Chemicals->
Wehrs Machine and Racing Products->
Shifters & Accessories->
Tools & Shop Supplies->
Transmissions & Converters->
MD/HD Truck & Bus->
Towing Accessories
Line Card
Michael's Swapmeet->
Gift Certificates

View All Products
View Price List
      Information      
F.A.Q.
Gift Voucher FAQ
Tech Tips
How To Set Your Valves
Torque Converter Order Form
About Us
View All Products
Contact Us
Privacy Notice
Shipping & Returns
Terms & Conditions
Links
Sitemap
      Articles      
All Articles 
 Before Buying A Shifter
 Care and Installation of your Undercover Innovations Products
 How To Set Your Valves
 Manufacturer Tech Contacts
 Which Hose Do I Need?
 How To Select The Right Performance Hose

Articles RSS Feed
Twitter
Stumbleupon
Reddit
Pintrest
Newsvine
Linkedin
Google+
Google
Facebook
Digg

WEGO III Wide-band Exhaust Gas Oxygen Sensor System - Automotive

 
Part Number: DS112002
 Racer Net: $547.50/Each
 Our Price: $438.00
 You Save: $109.50/Each (20%)

The WEGO III is a stand-alone unit with built-in data logging intended for harsh environments

WEGO Features and Benefits

  • Both WEGO III units are identical except that the dual channel unit displays and logs two channels of air/fuel (AFR) data and includes an input for a customer supplied flex fuel (ethanol) sensor.
  • Complete air/fuel ratio display system with built-in data logging.
    Includes WEGO 3 unit shown above, Bosch LSU4.2 5-wire wide-band oxygen sensor (two for dual channel system), sensor wire harness, 18x1.5mm weld nut(s) for mounting sensor on exhaust pipe, and software on CDROM.
  • WEGO units can be programmed to display Lambda or correct AFR values for any hydrocarbon fuel with a known stoichiometric ratio.
  • Versatile tuning aid for all carbureted and fuel injected engines displays air/fuel ratio (AFR) and logs over 2 hours data including AFR, engine RPM, and a spare 0-5V analog input for sensors such as throttle position or manifold pressure
  • Can be used for on-road or dyno testing
  • Suitable for automotive, motorcycle, and other small engine applications
  • Measurement range is 10.3 to 19.5 gasoline AFR or 0.70 to 1.33 Lambda
  • Highly accurate with less than 0.10 AFR or 0.007 Lambda error over entire range
  • Easy free-air calibration procedure corrects for sensor aging effects
  • 0-5V analog AFR output (two outputs for dual channel unit) for interface to dyno instrumentation
  • Ultra-bright daylight readable blue LED display with automatic dimming under low light conditions
  • Wide supply voltage range from 11-16V allows operation from battery on small engines or race vehicles without an alternator.
    Current draw is approx. 1 amp (2 amps for dual channel unit)
  • Built-in USB interface
  • Fully encapsulated with water-proof LED display
  • Compact size: 4"L x 2"W x 0.5"H (WEGO III Dual Display is 5.6"L x 3.2"W x 0.9"H)
  • Major WEGO Advantages over Competitive Systems

  • Data analysis. WEGO software allows you to analyze the data logged by the WEGO unit, not just print out a chart display. You can display and print out the required fuel correction (in percent) based on the AFR target value you select. You can then copy and paste this fuel correction data from the WEGO software to an Excel spreadsheet and then copy and paste from the Excel spreadsheet into your engine mapping software. No other system offers this capability.
  • Easy sensor free-air calibration. All WEGO systems provide quick and easy at-a-glance verification and adjustment of the sensor free-air calibration. This allows the WEGO to maintain accuracy as the sensor ages and maximizes sensor life in racing applications where the sensor may be exposed to leaded fuels.
  • Knowledgeable and prompt technical support. At Daytona Sensors, you can always reach a technician during normal business hours. You won't be told to send an email and wait for a response. An initial conversation is always with a trained technician. After hours and weekend support is available for racers.
  • The WEGO III is a third generation product that utilizes the proven Bosch LSU 4.2 wide-band exhaust gas oxygen sensor.
    By utilizing miniature surface mount electronics technology, digital signal processing techniques, and a switching power supply for the sensor heater, the WEGO III provides the same level of accuracy as lab systems costing thousands of dollars.
    All WEGO systems provide quick and easy at-a-glance verification and adjustment of the sensor free-air calibration.
    This allows the WEGO to maintain accuracy as the sensor ages and maximizes sensor life in racing applications where the sensor may be exposed to leaded fuels.

    Data Logging Software

    The WEGO features data logging and includes a built-in USB interface for easy connection to newer laptop PCs.
    This data logging capability greatly facilitates engine tuning and diagnosis of driveability issues.
    WEGO units start logging data once the sensors have warmed up (typically 15 seconds).
    The single channel WEGO stores the last 8000 samples in non-volatile memory.
    This allows storage ranging from 13 minutes at 10 samples/second to over 2 hours at 1 sample/second.
    The dual channel WEGO stores the last 12000 samples in non-volatile memory.
    This allows storage ranging from 20 minutes at 10 samples/second to over 3 hours at 1 sample/second.
    You can use our software to view data in real time or download and display data on a chart recorder type screen.
    Available data includes air/fuel ratio (AFR), RPM, and a 0-5V analog input.
    The RPM input can be connected to a tachometer signal or directly driven from an ignition coil.
    RPM data is correctly scaled and displayed for 1-12 cylinder engines.

    The data logging software runs under Microsoft Windows XP/Vista/7/8.
    We no longer support older Windows versions.
    Minimum PC requirement is a 300 MHz Pentium with super VGA display (SVGA with 1024 x 768 pixel resolution).
    WEGO units connect to the PC by means of a USB interface.
    A USB cable is supplied with the unit. The PC must have a free USB port.
    If you have an older PC without USB capability, you cannot use the WEGO. For more detailed product information, we suggest that you download the software and instructions.
    The software download includes a sample file with actual data.

    WEGO units can be programmed to display Lambda or correct AFR values for any hydrocarbon fuel with a known stoichiometric ratio.
    Regardless of the units displayed on the WEGO, data is logged internally in Lambda units and can be rescaled in the software for any fuel type.
    Refer to the software instructions for details.

    Click on PDF link for full

    PDF Datasheet--> View PDF Datasheet


    Back Write Review
     
    Related Products
    Related Categories
    Get a Shipping Estimate
    Twitter
    Stumbleupon
    Reddit
    Pintrest
    Newsvine
    Linkedin
    Google+
    Google
    Facebook
    Digg

     

    BizRate Customer Certified (GOLD) Site - Lyons Performance LLC Reviews at Bizrate

     

    CLASSIC - MOBILE View
    Copyright © 2018
    Lyons Performance LLC
    Ph: 203-506-6074
    Powered By osCommerce

     

          
    Popular Searches